Interface Specifications

Number of ports:
8
Connector:
RJ-21 (Female)
T1 Specifications
Line rate:
1.544Mbps
Line code:
AMI or B8ZS
Framing:
ESF, SF
E1 Specifications
Line rate:
2.0484Mbps
Line code:
AMI or HDB3
Framing:
G.704, CFC4 or no-CRC4

Other Specifications

Timing Source:
Loop timed, Card timed
Holdover Accuracy:
Stratum 4 local oscillator
RFC1661 – Point-to-Point Protocol (PPP)
RFC1990 – PPP Multilink Protocol (MP)
RFC1570 – PPP LCP Extensions
RFC3518 – Point-to-Point Protocol (PPP) Bridging
Control Protocol (BCP)

Power Requirements

Maximum power:
17W

Environmental Conditions

Operating Temp:
-40C to 65C
Storage Temp:
-40C to 75C
Relative Humidity:
5% to 95%, non-condensing

Regulatory Approvals

FCC Part 15 Class A/ANSI C63.4
EN 300 386 V1.3.1:2001-09/EN 55022:1998, Class A
VCCI Class A; ITE/ CISPR 22:1997 Class A
EN 300 386 V1.3.1:2001-09/EN 55022:1998, Class A
EN 300 386 V1.3.1:2001-09/EN 61000-4-3:1998
EN 300 386 V1.3.1:2001-09/EN 6100-4-6:1996
EN 300 386 V1.3.1:2001-09/EN 61000-4-4:1995
EN 300 386 V1.3.1:2001-09/EN 61000-4-5:1995
EN 300 386 V1.3.1:2001-09/EN 61000-4-2:1999
UL/cUL 60950: IEC60950
NEBS Level 3, GR-1089 Issue 3, GR63 Issue 2
USDA RUS
USA Headquarters
|
19800 North Creek Parkway
European Headquarters
|
Via Motta 24
Asia-Pacific Headquarters
|
11 Tai Seng Link
www.alliedtelesis.com
© 2006 Allied Telesis Inc. All rights reserved. Information in this document is subject to change without notice. All company names, logos, and product designs that are trademarks or registered trademarks are the property of their respective owners.

Ordering Information

NTE8
Model
NTE8
iMAP 9x00 Chassis
Model
iMAP 9700
iMAP 9700
iMAP 9400
iMAP 9400
MiniMAP 9101
MiniMAP 9102
iMAP Common Control
Model
CFC24
GE3
CFC56
XE1
CFC12
Related iMAP Line Cards and Accessories
Model
POTS24
CES8
PAC24
SHDSL24
VDSL24
ADSL24SA
NTE8 Cable
Filler
*Where XX
= 10 for U.S. power cord
= 30 for U.K. power cord
**Where YY
= 005 for 5 ft
= 010 for 10 ft
= 015 for 15 ft
= 020 for 20 ft
|
Suite 200
|
Bothell
|
6830 Chiasso
|
Switzerland
|
T: +41 91 69769.00
|
Singapore
|
534182
|
T: +65 6383 3832
Description
8 ports, T1/E1 MLPPP Service Module
Description
17-slot chassis with DC power with faceplates
17-slot chassis with DC power without faceplates
7-slot chassis with DC power with faceplates
7-slot chassis with DC power without faceplates
3-slot mini chassis with DC power
3-slot mini chassis with AC power
Description
24GbE switch controller card
3x GbE WAN interface card
56 GbE switch controller card
10GbE WAN interface card
12GbE switch controller card
Description
24-port, POTS Service Module
8-port, T1/E1 Circuit Emulation Service Module
24-port, POTS/ADSL2+ Combo w/Splitters, Annex A
24-port, G.SHDSL Service Module
24-port, VDSL2 Service Module, Annex B
24-port, ADSL2+ w/Splitters, Annex A
NTE8 RJ21 to Unterminated
Full size service slot filler plate
= 40 for Australia power cord
= 50 for Europe power cord
= 030 for 30 ft
= 040 for 40 ft
= 050 for 50 ft
= 060 for 60 ft
|
WA 98011
|
USA
|
T: +1 800 424 4284
|
F: +41 91 69769.11
|
F: +65 6383 3830
Part #
AT-TN-125-A
Part #
AT-TN-250GF
AT-TN-250G
AT-TN-251GF
AT-TN-251G
AT-TN-9101-A-80
AT-TN-9102-A-XX*
Part #
AT-TN-401-B
AT-TN-301-A
AT-TN-407-A
AT-TN-308-A
AT-TN-408-A
Part #
AT-TN-113-A
AT-TN-119-A
AT-TN-123-A
AT-TN-127-A
AT-TN-128-A
AT-TN-129-A
AT-TN-C021-A-YY**
AT-TN-M000-A
= 070 for 70 ft
= 080 for 80 ft
= 090 for 90 ft
|
F: +1 425 481 3895