TROUBLE SHOOTING
TROUBLES
1. Unit does not
Start when
Pressing on/off
Button
2. Not cool enough
3. Power shut off at
Heating mode
4. Noisy or vibration
5. Gurgling sound
6. Compressor does not work
and the digital display area
shows
P2
7. The cooling indicator light
flashes at 1Hz and the digital
display area shows
E1
8. The FAN indicator light
flashes at 1Hz and the digital
display area shows
E2
9. The
Dehumidifying
indicator
light flashes at 1Hz and the
digital display area shows
E3
POSSIBLE CAUSES
- Water full indicator blinks, water tank
is full.
- Room temperature is higher than
the set temperature.(Heating mode)
- Room temperature is lower than
the set temperature.(Cooling mode)
- The windows or doors in the room
are not closed.
- There are heat sources inside the
room.
- Exhaust air duct is not connected or
blocked.
- Temperature setting is too high.
- Air filter is blocked by dust.
- The automatic over heat protection
function. When the temperature at
the air outlet exceed 70 C/158 F,the
device will stop.
- The ground is not level or not flat
enough.
- The sound comes from the flowing
of the refrigerant inside the
air-conditioner.
- The bottom tray is full
- The room temperature Sensor is
off or short-circuit.
- The Evaporator Temperature Sensor
is off or short-circuit.
- The Condenser Temperature Sensor
is off or short-circuit.
TROUBLESHOOTING TIPS
SUGGEST REMEDIES
Dump the water in the water tank.
Reset the temperature.
Reset the temperature.
Make sure all the windows and
doors are closed.
Remove the heat sources if possible.
Connect the duct and make
sure it can function properly.
Decrease the set temperature.
Clean the air filter.
Switch on again after the unit
has cool down.
O
O
Place the unit on a flat, level
ground if possible.
It is normal.
Rremove the bottom plug and drain
the collected water away. If it does
not work after restart, contact the
service people.
Contact service people
Contact service people
Contact service people
18