Chris Coffee Service Silvano Manuale d'uso - Pagina 18

Sfoglia online o scarica il pdf Manuale d'uso per Caffettiera Chris Coffee Service Silvano. Chris Coffee Service Silvano 20. Pid controlled espresso machine

Troubleshooting – Continued

Not Heating

 Verify the machine is plugged into the outlet
and the outlet has power. Verify the power switch
is in the ON "2" position.
 Check the resettable hi-limit switch on the left side
of the boiler. Unplug the machine from the outlet
and remove the top panel. Locate the resettable
hi-limit switch shown in the picture to the right.
 Press the center button in firmly to reset.
 Install the top cover back on the machine and then plug it back into the outlet and
test.
 If the machine still does not heat then contact your distributor for service.
No Power To The PID Controller
 Make sure the main power switch is in the ON "2" position.
 Press the reset button on the left side of the coffee boiler shown in the picture below.
Silvano Espresso Machine
17