Dell EMC VxRail E560F Manuale d'uso - Pagina 18
Sfoglia online o scarica il pdf Manuale d'uso per Server Dell EMC VxRail E560F. Dell EMC VxRail E560F 35. Appliances on poweredge servers
Figure 9. AC PSU status indicator
1. AC PSU status indicator/handle
Table 16. AC PSU status indicators
Convention
A
B
C
D
E
18
Overview
Power indicator
pattern
Green
Flashing green
Flashing green and turns
off
Flashing amber
Not lit
Condition
A valid power source is connected to the PSU and the PSU is operational.
When the firmware of the PSU is being updated, the PSU handle flashes
green.
When hot-adding a PSU, the PSU handle flashes green five times at 4
Hz rate and turns off. This indicates a PSU mismatch with respect to
efficiency, feature set, health status, and supported voltage.
NOTE:
Ensure that both the PSUs are of the same capacity.
CAUTION:
For AC PSUs, use only PSUs with the Extended Power
Performance (EPP) label on the back.
Indicates a problem with the PSU.
CAUTION:
When correcting a PSU mismatch, replace only the
PSU with the flashing indicator. Swapping the PSU to make a
matched pair can result in an error condition and unexpected
appliance shutdown. To change from a high output configuration
to a low output configuration or vice versa, you must turn off the
appliance.
CAUTION:
AC PSUs support both 220 V and 110 V input voltages.
When two identical PSUs receive different input voltages, they
can output different wattages, and trigger a mismatch.
CAUTION:
If two PSUs are used, they must be of the same type
and have the same maximum output power.
CAUTION:
Combining AC and DC PSUs is not supported and
triggers a mismatch.
Power is not connected.