Dell PowerConnect M8428-k Manuale - Pagina 25
Sfoglia online o scarica il pdf Manuale per Server Dell PowerConnect M8428-k. Dell PowerConnect M8428-k 25. Dell poweredge m710 and m710hd - system memory update
Anche per Dell PowerConnect M8428-k: Manuale di aggiornamento (32 pagine), Note di rilascio (27 pagine), Manuale d'uso (23 pagine), Manuale di aggiornamento (1 pagine)

chassisaction –m switch-<n> powercycle
where <n> is the switch number [1-6].
5.3
Resolving a Link Protocol Mismatch
Log in to 10GbE PTM CLI and run the "show port link" command. Check the status of the down-
link and uplink in the relevant port to identify the mismatch – see
5.4
Resolving CLI Connectivity Problems
Reboot the 10GbE PTM through the CMC CLI using the following command:
chassisaction –m switch-<n> powercycle
where <n> is the switch number [1-6].
5.5
Recovery From Non-Responsive 10GbE PTM CLI
Reboot the 10GbE PTM through the CMC CLI using the following command:
chassisaction –m switch-<n> powercycle
where <n> is the switch number [1-6].
5.6
Recovery From a Software Update Failure
1. Reboot the 10GbE PTM through the CMC CLI using the following command:
chassisaction –m switch-<n> powercycle
where <n> is the switch number [1-6].
2. Restart the software update process.
Section 3.7.2
for details.
Rev 1.00
25