Dell PowerEdge 2410 Manuale - Pagina 10

Sfoglia online o scarica il pdf Manuale per Server Dell PowerEdge 2410. Dell PowerEdge 2410 11. Cabling poweredge t610
Anche per Dell PowerEdge 2410: Manuale (20 pagine), Manuale (20 pagine), Manuale (17 pagine), Manuale (12 pagine), Manuale (10 pagine), Manuale (10 pagine), Manuale (9 pagine), Manuale (9 pagine), Manuale (10 pagine), Manuale (12 pagine), Manuale (8 pagine)

Dell PowerEdge 2410 Manuale
Cable Routing Procedures for Dell™ PowerEdge™ R515 Systems
Section 3: Replacing a Power Supply on a PowerEdge™ R515 System With a
CMA

3.1 Replacing a Power Supply with a Left-Side Mounted CMA

1.
If the bottom power supply must be replaced, then remove the tray from underneath the CMA
as described in the
supply must be replaced, this step can be skipped.
2. Swing the CMA to its service position.
3. Disconnect the power cord from the power supply and disengage the strain relief.
4. Replace the power supply.
5. Plug in the power cord, re-engage the strain relief, replace the CMA support tray (if it was
removed), and return the CMA to the closed (retracted) position.

3.2 Replacing a Power Supply with a Right-Side Mounted CMA

1.
If the bottom power supply must be replaced, then remove the tray from underneath the CMA
as described in the
supply must be replaced, this step can be skipped.
2. Swing the CMA to its service position.
3. Disconnect the inner CMA bracket from the rail as shown in Figure 9.
4. While supporting the CMA with one hand, remove and replace the power supply with the
other hand as shown in Figure 10.
5. Reinstall the inner CMA bracket to reconnect the CMA.
6. Plug in the power cord, re-engage the strain relief, replace the CMA support tray (if it was
removed), and return the CMA to the closed (retracted) position.

Figure 9: Disconnecting the Inner CMA Attachment Bracket

CMA Installation Instructions
CMA Installation Instructions
provided with the CMA kit. If the top power
provided with the CMA kit. If the top power
Page 8