Dell PowerEdge 6850 Manuale d'uso - Pagina 3
Sfoglia online o scarica il pdf Manuale d'uso per Server Dell PowerEdge 6850. Dell PowerEdge 6850 29. Information update (.pdf)
Anche per Dell PowerEdge 6850: Manuale di sostituzione della scheda di sistema (2 pagine), Aggiornamento delle informazioni (1 pagine)
Video
Video type
Video memory
Power
AC power supply (per power supply)
Wattage
Voltage
Heat dissipation
Maximum inrush current
Batteries
System battery
ROMB battery (optional)
Physical
Height
Width
Depth
Weight (maximum configuration)
Environmental
NOTE:
For additional information about environmental measurements for specific system configurations, see
www.dell.com/environmental_datasheets.
Temperature
Operating
Storage
Relative humidity
Operating
Storage
Maximum vibration
Operating
Storage
Maximum shock
Operating
Storage
Altitude
Operating
Storage
Back to Contents Page
ATI Radeon 7000 video controller; VGA connectors
16 MB
1470 W
170–264 VAC, autoranging, 47–63 Hz, 11.43 A
1614.3 BTU/hr maximum
Under typical line conditions and over the entire
system ambient operating range, the inrush current
may reach 55 A per power supply for 10 ms or less
and 25 A per power supply for up to 150 ms.
CR 2032 3.0-V lithium ion coin cell
4.1-V lithium ion
17.27 cm (6.8 in)
44.70 cm (17.6 in)
70.10 cm (27.6 in)
41.73 kg (92 lb)
10° to 35°C (50° to 95°F)
–40° to 65°C (–40° to 149°F)
8% to 85% (noncondensing) with a maximum
humidity gradation of 10% per hour
5% to 95% (noncondensing)
0.25 G at 3–200 Hz for 15 min
0.5 G at 3–200 Hz for 15 min
One shock pulse in the positive z axis (one pulse on
each side of the system) of 41 G for up to 2 ms
Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse on
each side of the system) of 71 G for up to 2 ms
–16 to 3048 m (–50 to 10,000 ft)
–16 to 10,600 m (–50 to 35,000 ft)