Dell PowerEdge C5220 Manuale tecnico - Pagina 28

Sfoglia online o scarica il pdf Manuale tecnico per Server Dell PowerEdge C5220. Dell PowerEdge C5220 32. Poweredge series
Anche per Dell PowerEdge C5220: Manuale del portafoglio (27 pagine), Rapporto di prova (13 pagine)

Dell PowerEdge C5220 Manuale tecnico

Environmental specifications

Table 17 details the environmental specifications for the PowerEdge C5220. For the most up-to-
date information, see the
Dell.com/Support/Manuals.
specific system configurations, see Dell.com/environmental_datasheets.
Temperature
Operating
10° to 35°C (50° to 95°F) with a maximum temperature gradation of 10°C per hour. Note:
For altitudes above 2950 feet, the maximum operating temperature is de-rated 1°F/550 feet
Storage
-40° to 65°C (-40° to 149°F) with a maximum temperature gradation of 20°C per hour
Relative humidity
Operating
20% to 80% (non-condensing) with a maximum humidity gradation of 10% per hour
Storage
5% to 95% (non-condensing)
Maximum vibration
Operating
0.26 Grms at 5Hz to 350Hz for 5 minutes in operational orientations
Storage
1.87 Grms at 10Hz to 500Hz for 15 minutes in all orientations
Maximum shock
Operating
One shock pulse in the positive z-axis (one pulse on each side of the system) of 31G for
2.6ms in the operational orientation
Storage
Six consecutively executed shock pulses in the positive and negative x, y and z axes (one
pulse on each side of the system) of 71G for up to 2ms.
Six consecutively executed shock pulses in the positive and negative x, y and z axes (one
pulse on each of the system) of 22G faired square wave pulse with velocity change at
200in/second (508cm/sec)
Altitude
Operating
-16 to 3048 m (-50 to 10,000 ft) Note: For altitudes above 2950 feet, the maximum
operating temperature is de-rated 1°F/550 ft
Storage
-16 to 10,600 m (-50 to 35,000 ft)
Note: For altitudes above 2950 feet, the maximum operating temperature is de-rated
1°F/550 ft
Airborne contaminant level
Class G1 or lower as defined by ISA-S71.04-1985
28
PowerEdge C5220 Technical Guide
Dell PowerEdge C5220 Getting Started Guide
For additional information about environmental measurements for
Table 17.
Environmental specifications