Dell PowerEdge C6105 Manuale d'uso - Pagina 13
Sfoglia online o scarica il pdf Manuale d'uso per Server Dell PowerEdge C6105. Dell PowerEdge C6105 46. Rack server
Anche per Dell PowerEdge C6105: Manuale del portafoglio (27 pagine), Manuale tecnico (36 pagine)
Front Panel User Interface
The BMC provides control panel interface functionality including indicators
(fault, status, and ID LEDs) and buttons (power/ID).
Power Button
The power button turns the device on and off.
ID Button
The control panel Chassis Identify button toggles the state of the Chassis ID
LED. If the ID LED is off, pressing the button turns the LED on (blinking).
If the LED is on, pressing the button or an IPMI Chassis Identify command
turns the LED off.
LEDs
BMC Heartbeat LED
The green LED provides an easy way to indicate that BMC is now enabled.
ID LED
A blinking LED indicates the Chassis Identify command has been accepted.
System Status LED
There is a dual-color LED to show the system status. The BMC turns the
LED off after all event logs are cleared.
The behavior of Status LED and ID LED is listed in Table 1-2.
Table 1-2. LED Status
LED
Status LED
Color
Status
Amber
Blinks
Off
Green
On
Blinks
Off
When
See "Blinking Health LED
Conditions" on page 14.
Normal status
Amber LED is off
Amber LED is blinking
DC off
13