Dell PowerEdge C6145 Manuale tecnico - Pagina 30
Sfoglia online o scarica il pdf Manuale tecnico per Server Dell PowerEdge C6145. Dell PowerEdge C6145 34. Rack server
Anche per Dell PowerEdge C6145: Manuale del portafoglio (27 pagine)
Temperature
Operating
10° to 35° C (50° to 95° F) with a maximum temperature gradation of 10° C per hour. Note:
For altitudes above 2950 feet, the maximum operating temperature is de-rated 1°F/550 ft
Storage
-40° to 65° C (-40° to 149° F) with a maximum temperature gradation of 20° C per hour
Relative humidity
Operating
20% to 80% (non-condensing) with a maximum humidity gradation of 10% per hour
Storage
5% to 95% (non-condensing) with a maximum humidity gradation of 10% per hour
Maximum vibration
Operating
0.26 Grms at 5Hz to 350Hz for 5 minutes in operational orientations
Storage
1.88 Grms at 10Hz to 500Hz for 15 minutes in all orientations
Maximum shock
Operating
One shock pulse in the positive z-axis (one pulse on each side of the system) of 31G for
2.6ms in the operational orientation
Storage
Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one
pulse on each side of the system) of 71G for up to 2ms.
Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one
pulse on each of the system) of 27G faired square wave pulse with velocity change at
235in/second (597cm/sec)
Altitude
Operating
-16 to 3048 m (-50 to 10,000 ft) Note: For altitudes above 2950 feet, the maximum
operating temperature is de-rated 1°F/550 ft
Storage
-16 to 10,600 m (-50 to 35,000 ft)
Airborne contaminant level
Class G1 or lower as defined by ISA-S71.04-1985
Video specifications
The baseboard management controller (BMC) for the PowerEdge C6145 incorporates an integrated
video subsystem that is connected to the 32-bit PCI interface of the ICH10R. The logic is based on
the ATS2050 and supports 2D graphics only. The video device output is available only as a rear video
port. The integrated video core shares its video memory with the BMC's 64MB DDR2 application
space memory. This memory is also used for the KVM buffer. Table 18 lists the supported video
modes.
Resolution
640 x 480
800 x 600
1024 x 768
1152 x 864
1280 x 1024
30
Dell PowerEdge C6145 Rack Server Technical Guide
Table 17.
Environmental specifications
Table 18.
Supported video modes
Refresh Rate (Hz)
60, 72, 75, 85
56, 60, 72, 75, 85
60, 72, 75, 85
75
60, 75, 85
Color Depth (bit)
8, 16, 32
8, 16, 32
8, 16, 32
8, 16, 32
8, 16