Anche per Dell PowerEdge M420: Aggiornamento delle informazioni (38 pagine), Note di rilascio (27 pagine), Manuale (25 pagine), Manuale d'uso (23 pagine), Informazioni importanti Manuale (35 pagine), Manuale di aggiornamento (28 pagine), Manuale d'uso (26 pagine), Manuale d'uso (22 pagine), Manuale introduttivo (12 pagine), Manuale (38 pagine), Manuale tecnico (46 pagine), Manuale tecnico (48 pagine), Manuale del portafoglio (27 pagine), Manuale introduttivo (14 pagine), Manuale introduttivo (12 pagine)

Dell PowerEdge M420 Manuale di aggiornamento
Host Interface Card

Installation Instructions

1 Install the Dell X410 Host Interface Card (HIC) in an available x16 PCIe slot
in the host.
2 Connect the Dell X410 HIC port to the C410x, with the provided cables.
NOTE:
For R710 systems, it is recommended that you install the optional x16 riser 2 to
accommodate the HIC card and provide optimal bandwidth.
NOTE:
For information on Graphics Processing Unit (GPU) system configuration design,
see Flexibility: The Dell Approach to HPC GPU Computing at HPCatDell.com.
C410x PCIe Expansion Chassis
For more information, see the C410x Hardware Owner's Manual at
support.dell.com/manuals.
NOTE:
Due to limited system resources for PCIe devices, the C410x does not support
the 8:1 mode in the M610x, R710, and R410 systems. Ensure that the C410x port
configuration mode is set to either 2:1 or 4:1 mode.

Power Sequencing Requirements

To ensure proper operation with the host platform, follow specific power
sequencing requirements.
Turning on the Host
1 Turn on the C410x.
NOTE:
2 Turn on the host.
Rebooting the Host
1 Turn off the host.
2 Turn off the C410x.
3 Turn on the C410x.
NOTE:
4 Turn on the host.
Wait for the GPU power button LED on the chassis to light.
Wait for the GPU power button LED on the chassis to light.