Dell PowerEdge M420 Manuale tecnico - Pagina 28

Sfoglia online o scarica il pdf Manuale tecnico per Server Dell PowerEdge M420. Dell PowerEdge M420 48. Dell poweredge blade servers getting started guide
Anche per Dell PowerEdge M420: Aggiornamento delle informazioni (38 pagine), Note di rilascio (27 pagine), Manuale (25 pagine), Manuale d'uso (23 pagine), Informazioni importanti Manuale (35 pagine), Manuale di aggiornamento (32 pagine), Manuale di aggiornamento (28 pagine), Manuale d'uso (26 pagine), Manuale d'uso (22 pagine), Manuale introduttivo (12 pagine), Manuale (38 pagine), Manuale tecnico (46 pagine), Manuale del portafoglio (27 pagine), Manuale introduttivo (14 pagine), Manuale introduttivo (12 pagine)

Dell PowerEdge M420 Manuale tecnico

8 Power, thermal and acoustics

Lower overall system-level power draw is a result of Dell's breakthrough system design. The
PowerEdge M420 blade server and M1000e chassis enclosure maximize performance per watt
through a combination of power and cooling, energy-efficient technologies and tools. Additionally,
the M420 has an extensive collection of sensors that automatically track thermal activity, which
helps regulate temperature thereby reducing server noise and power consumption.

Power consumption and energy efficiency

With the rise in the cost of energy coupled with increasing data center density, Dell provides tools
and technologies to help you realize greater performance with less energy cost and waste. More
efficient data center usage can reduce costs by slowing the need for additional data center space.
Table 14 lists the tools and technologies Dell offers to help you achieve your data center goals by
lowering power consumption and increasing energy efficiency.
Feature
Power supply units (PSU)
portfolio
Tools for right-sizing
Industry compliance
Power monitoring accuracy
Power capping
Systems management
PowerEdge M420 Technical Guide
28
Table 14.
Power tools and technologies
Description
Dell's PSU portfolio includes intelligent features such as dynamically optimizing
efficiency while maintaining availability and redundancy.
Energy Smart Solution Advisor (ESSA) is a tool that helps you determine the
most efficient configuration possible. With Dell's ESSA, you can calculate the
power consumption of your hardware, power infrastructure and storage. ESSA
can help you determine exactly how much power your server will use at a
given workload, and the PSU Advisor can help you choose the best, most
efficient PSU for your workload. Learn more at Dell.com/ESSA.
Dell's servers are compliant with all relevant industry certifications and
guidelines, including 80 PLUS, Climate Savers and
Dell's power monitoring accuracy is currently 1%, whereas the industry
standard is 5%. PSU power monitoring improvements include:
More accurate reporting of power
Better performance under a power cap
Use Dell's systems management to set the power cap limit for your systems to
limit the output of a PSU and reduce system power consumption. Dell is the
first hardware vendor to leverage Intel Node Manager for circuit-breaker fast
capping.
iDRAC7 Enterprise provides server-level management that monitors, reports
and controls power consumption at the processor, memory and system level.
Dell OpenManage Power Center delivers group power management at the
rack, row and data center level for servers, power distribution units and
uninterruptible power supplies.
®
ENERGY STAR
.