Dell PowerEdge R320 Manuale introduttivo - Pagina 9
Sfoglia online o scarica il pdf Manuale introduttivo per Server Dell PowerEdge R320. Dell PowerEdge R320 11. Poweredge series
Anche per Dell PowerEdge R320: Manuale (11 pagine), Specifiche (2 pagine), Manuale del portafoglio (27 pagine), Manuale introduttivo (9 pagine), Manuale introduttivo (9 pagine)
Physical
Depth (includes bezel)
With cabled power supply
unit
With redundant power
supply unit
Weight (maximum)
Weight (empty)
Environmental
NOTE: For additional information about environmental measurements for specific
system configurations, see dell.com/environmental_datasheets.
Temperature
Operating
Storage
Relative humidity
Operating
Storage
Maximum vibration
Operating
Storage
660.2 mm (25.99 inch)
677.3 mm (26.66 inch)
19.3 kg (42.55 lb)
16.33 kg (36 lb)
Continuous operation: 10 °C to 35 °C at 10% to 80%
relative humidity (RH), with 26 °C max dew point.
De-rate maximum allowable dry bulb temperature at
1 °C/300 m above 900 m (1°F per 550 ft).
NOTE: For information on supported expanded
operating temperature range and
configurations, see support.dell.com/manuals.
–40 °C to 65 °C (–40 °F to 149 °F) with a maximum
temperature gradation of 20 °C per hour
20% to 80% (noncondensing) at a maximum wet
bulb temperature of 29 °C (84.2 °F)
5% to 95% at a maximum wet bulb temperature of 38
°C (100.4 °F)
0.26 G
at 5 Hz to 350 Hz (all operation
rms
orientations)
1.87 G
at 10 Hz to 500 Hz for 15 min (all six sides
rms
tested)
9