Sfoglia online o scarica il pdf Manuale di installazione per Sistema idrico EarthLinked HCM-4272C. EarthLinked HCM-4272C 11. Hybrid cooling module
Pre-Installation
This EarthLinked® Hybrid Cooling Module (HCM) is for use with EarthLinked®
space heating and cooling systems that provide cooling. The HCM is a
required component of the EarthLinked® systems where indicated in the
EarthLinked® Performance Tables for R-410A systems.
This Hybrid Cooling Module (HCM) is sold as a system component and must be properly matched
with the compressor unit to provide the anticipated performance and safe operation of the system.
The table below lists the properly matched EarthLinked
®
EarthLinked
compressor unit models.
If the HCM is installed as a retrofit, the refrigerant charge in the existing system must be
recovered before HCM installation. Use new refrigerant to recharge the system.
Application of the Hybrid Cooling Module (HCM) to EarthLinked
use of two (2) field supplied Type ACR copper couplings to match the HCM with the line set
vapor tube size. See the table below to determine the required coupling sizes.
Compressor
Unit Model
-018
-024,-025
-030
-036
-040
-042
-048
-050
-054
-060
-066,-068
-072
.
Before installing this Hybrid Cooling Module (HCM), be sure that all electrical
power to the EarthLinked® system is "OFF". Wear adequate protective
clothing and practice all applicable safety precautions within installating this
equipment. Failure to do so may result in equipment and/or property damage,
personal injury or death.
HCM-410CP-IM (12/15)
IMPORTANT!
COMPRESSOR UNIT/HCM MODEL MATCH
Hybrid Cooling Module
Connections
Model HCM
-1836C
-4272C
WARNING!
®
Hybrid Cooling Module models with
®
systems will require the
Vapor Line Set Size,
OD, in.
R-410A
OD, In.
7/8
1-1/8
1-1/8
1-1/8
5/8
5/8
3/4
3/4
3/4
3/4
7/8
7/8
7/8
7/8