Port Status field
Port Type field
PortStats tab
4-Byte Word
Transmitted field
4-Byte Word
Received field
Frames Transmit-
ted field
Frames Received
field
C2 Frames
Received field
C3 Frames
Received field
No_Module — No GBIC module in this port
No_Light — The module is not receiving light
No_Sync — The module is receiving light but is out
of sync
In_Sync — The module is receiving light and is in
sync
Laser_Flt — The module is signaling a laser fault
(defective GBIC)
Port_Flt — The port is marked faulty (defective
GBIC, cable, or device)
Diag_Flt — The port failed diagnostics
Online — The port is up and running
Lock_Ref — The port is locking to the reference
signal
E-Port — Switch link port
G-Port — Generic port
U-Port — Universal port
F-Port — Fabric port
FL-Port — Fabric loop port
L-Port — Loop port
Number of four-byte words transmitted
Number of four-byte words received
Number of frames transmitted
Number of frames received
Number of class 2 frames received
Number of class 3 frames received
Using the Dell PowerVault Switch Manager
2-19