Dell PowerVault LTO-3-060 Manuale d'uso - Pagina 10
Sfoglia online o scarica il pdf Manuale d'uso per Immagazzinamento Dell PowerVault LTO-3-060. Dell PowerVault LTO-3-060 37. Powervault tape systems
Anche per Dell PowerVault LTO-3-060: Impostazione (2 pagine), Manuale (28 pagine)
1. Power connector
2. SCSI ID connector
3. SCSI connector
Status LEDs
Each status LED has four modes:
OFF
l
ON
l
Flashing slowly (at 2 Hz)
l
Flashing rapidly (at 8 Hz)
l
Operating Modes
The drive functions in the following modes:
Operation mode - functions include using data and cleaning cartridges, reporting errors and updating firmware. For more information, see
l
of status LEDs in Operation mode (No Errors)
Service mode - functions include a drive diagnostic test and methods of saving or erasing drive diagnostic information called a "dump" which can then be used by
l
trained service personell to troubleshoot a tape problem. For more information, see
The Unload button is used to switch between modes. For more information, see
Unload Button
The Unload button (1) in
Figure 2
performs the following functions:
Table 1. Functions that the Unload button performs
Unload button function
Rewind the tape into the cartridge and
eject the cartridge from the drive
Exit Operation mode and Enter Service
mode
Scroll through the Service Functions
Exit Service mode and Enter Operation
mode
Force a drive dump
below.
How to initiate the function
Press the Unload button once. The Activity LED flashes green while the drive is rewinding and unloading.
Ensure that the drive is unloaded. Then, press and hold the Unload button until the Ready LED begins flashing rapidly
(approximately 6 seconds).
Note: While in Service mode, the drive does not accept commands from the server.
While in Service mode, press the Unload button once per second to increment the Service Functions by one. When you
reach the desired Service Functions, select it by either inserting a cartridge into the drive (Service Function 1) or double-
clicking the Unload button (Service Functions 2, 4, and 5). See
Press the Unload button once per second until you have scrolled through all Service mode selections. Service mode is
exited when all LEDs are off except for Ready LED which is on solid. The drive will exit Service mode if there is no Unload
button activity for 15 seconds. See
Attention: If the drive detects a permanent error, it automatically forces a drive dump (also known as a save of the
firmware trace). Captured dump data is placed in drive RAM. If you force a drive dump, the existing dump will be
overwritten and it will be lost. After you force a drive dump, do not turn off the power to the drive or you may lose the
dump data. To permanently save a dump to non volatile memory, see
dump that is saved to flash memory will persist thru a drive power cycle.
To force a dump, choose one of the following procedures:
If the drive is in Service mode, scroll to and select Service Function 2 (see
l
dump).
If the drive is in Operation mode, press and hold the Unload button for 12 seconds.
l
Service Mode
in the Troubleshooting section.
Unload
Button.
Table 1. Service Mode
Table 1. Service Mode
for more information.
Executing Service Function 4: Copy dump to
Table 2. Interpretation
for more information.
flash. A
Executing Service Function 2: Force