Dell PowerVault MD3000i Manuale di aggiornamento - Pagina 2

Sfoglia online o scarica il pdf Manuale di aggiornamento per Immagazzinamento Dell PowerVault MD3000i. Dell PowerVault MD3000i 28. Configuration for vmware esx server software
Anche per Dell PowerVault MD3000i: Manuale di sintonizzazione (32 pagine), Nota di supporto (22 pagine), Manuale d'uso (46 pagine), Manuale di sostituzione (4 pagine), Manuale di configurazione (10 pagine)

Dell PowerVault MD3000i Manuale di aggiornamento
Adding a RAID Controller Module to a Simplex
Configuration
To upgrade your existing simplex storage array to a duplex storage array,
perform the following steps:
1 Start MD Storage Manager.
2 Choose the storage array you are upgrading and click the Support tab.
3 Select Download Firmware.
If both the RAID controller module firmware and NVSRAM need
to be applied, select Download RAID Controller Module Firmware.
Select the Transfer NVSRAM file with RAID controller module
firmware box and use Select File to navigate to the most recent
version of the duplex NVSRAM firmware you downloaded from
support.dell.com.
If only the RAID controller module NVSRAM needs to be applied,
select Download RAID Controller Module NVSRAM and use Select
File to navigate to the most recent version of the duplex NVSRAM file
you downloaded from support.dell.com.
4 From the command line of the management station you use to manage
the storage array, change the array mode from simplex to duplex
(where IP_address is the management port address of RAID controller 0):
NOTE:
the path you selected during installation of management station software
for MD Storage Manager.
SMcli IP_address -c
"set storageArray redundancyMode=duplex;"
NOTE:
Needs Attention and the enclosure status LED lights amber. Disregard these
indicators and proceed with the next step.
5 Insert the second (new or replacement) RAID controller module in the
empty slot (slot 1) of the RAID enclosure. For proper insertion procedures
and slot labeling, see the Dell™ PowerVault™ MD 3000i Hardware Owner's
Manual.
The SMcli command is installed under the client directory of
When the SMcli command completes, the array status changes to