Dell PowerVault MD3200i Series Manuale tecnico - Pagina 7

Sfoglia online o scarica il pdf Manuale tecnico per Immagazzinamento Dell PowerVault MD3200i Series. Dell PowerVault MD3200i Series 38. Storage arrays
Anche per Dell PowerVault MD3200i Series: Manuale d'uso (41 pagine), Manuale di aggiornamento (32 pagine), Istruzioni per l'installazione del rack (2 pagine), Manuale d'uso (46 pagine), Matrice di supporto (12 pagine), Manuale di installazione (18 pagine), Aggiornamento delle informazioni (1 pagine), Matrice di supporto (11 pagine), Matrice di supporto (17 pagine), White Paper (22 pagine), Manuale (16 pagine)

Dell PowerVault MD3200i Series Manuale tecnico
DELL PowerVault MD3200i/MD3220i Technical Guide Book

Controller Architecture

Figure 1.
RAID controller architecture of the MD3200i controller.
RJ
RJ45
45
32-lane 8-port
1Gb Eth
PCI-E
NIC
PCI-E Switch
2GB
DDR-II
DDR-II
SD
Flash
Flash
BBU
FPGA
Cache Offload
Assembly
NVSRAM
SBB 2.0 Compliant Connector
The RAID controllers are the "engines" or the "brains" of the MD3200i and MD3220i storage arrays.
They perform the RAID calculations, control the I/O movement, communicate with the management
client, store the firmware, and protect data until it can be written safely to the hard disk drives. The
MD3200i's architecture is designed to excel in multi-host systems environments. Its I/O system core
provides built-in hardware XOR for high-speed RAID parity calculations – enabling it to easily handle
very compute-intensive tasks. Each RAID controller contains 2GB of cache for a total of 4GB of cache
in a dual controller configuration which is mirrored with the other controller's cache for high
availability. In the event of a power failure, the controllers are protected with battery assisted
persistent cache backup which destages cache to non-volatile media for indefinite safe keeping.
Each controller has a 36-port 6 Gb/s SAS expander that provides access to the drives in the MD3200i or
MD3220i enclosure. The SAS expanders enable each controller to access all of the drive ports creating
active/active drives loops that provide both controllers redundant access to all attached disk drives.
RJ45
RJ45
RJ45
iSCSI TOE
800MHz
Power PC
X4
(Alt Ctrl)
SAS
Exp
X4
6Gb SAS
36 Port
Expander
X4
X24
X4
(Drives)
(Alt Ctrl)
5