Dell PowerVault MD3420 Manuale d'uso - Pagina 14

Sfoglia online o scarica il pdf Manuale d'uso per Immagazzinamento Dell PowerVault MD3420. Dell PowerVault MD3420 47. Storage arrays
Anche per Dell PowerVault MD3420: Manuale introduttivo (8 pagine), Manuale d'uso (27 pagine)

Dell PowerVault MD3420 Manuale d'uso
Item
Component
1
12Gbps SAS IN port (2)
2
Seven segment display
sequence
3
Controller power LED
4
Controller fault LED
5
System identification LED
6
Cache active or cache offload
LED
7
Battery fault
8
Management port
9
Ethernet port (reserved)
10
12Gbps SAS IN port (2)
11
USB port
12
Mini USB port
13
Password reset switch
14
SAS OUT Port (2)
RAID Controller Module—Additional Features

Battery Backup Unit

Each RAID controller contains a two-cell Lithium ion nanopolymer battery backup unit (BBU). It provides
power to the RAID controller module in the event of a power outage. For information on removing and
installing the BBU, see
RAID Controller Module Backup Battery Unit
NOTE: For virtual disks, the RAID controller firmware changes the data cache setting based on the
state of the battery. If the battery is missing or does not have sufficient charge, the controller flushes
the cache and sets the write cache attribute to Write Through for all virtual disks. When the battery
is replaced, Write Back is re-enabled.
14
Function
Provides host-to-controller SAS connection.
Displays status or error codes for the storage array.
Lights green when controller power is on.
Turns off when controller is not powered.
Lights amber when controller fault is detected.
Turns off when controller is operating normally
Blinks blue when system identification switch push-
button on enclosure front panel is pressed.
Lights green when on-board controller memory
contains data.
If AC power fails, this LED changes to indicate Cache
offload status. If the password reset function has
successfully changed the password, this LED flashes
on and off briefly.
Lights amber when battery backup unit or battery has
failed.
Turns off when battery backup unit is operating
normally
Provides a 100/1000 Mbps Ethernet connection for
out-of-band management of the enclosure.
Reserved port.
Provides host-to-controller SAS connection.
Reserved port.
Provides serial connection for debugging.
Activating this switch resets the password.
Provides SAS connection for cabling to a downchain
expansion enclosure.
Using Port 0 is recommended.
.