Dell PowerVault MD3660f Series Manuale d'uso - Pagina 22

Sfoglia online o scarica il pdf Manuale d'uso per Immagazzinamento Dell PowerVault MD3660f Series. Dell PowerVault MD3660f Series 26. Storage arrays
Anche per Dell PowerVault MD3660f Series: Manuale hardware e software (25 pagine), Manuale di installazione (11 pagine), Manuale introduttivo (10 pagine), Aggiornamento delle informazioni (8 pagine), Istruzioni per l'installazione del rack (2 pagine), Impostazione (2 pagine), Manuale di configurazione (17 pagine), Manuale d'uso (24 pagine)

Dell PowerVault MD3660f Series Manuale d'uso
Figure 1. Installing and Removing an SFP Module

Removing SFP Modules

To remove SFP modules:
1.
Remove the FC cable from the SFP module.
See
Removing Fibre Channel
NOTE: To avoid damaging the cable or the SFP module, disconnect the FC cable before removing the SFP
module.
2.
Unlock the SFP module latch. For SFP modules that contain wire tabs, unlock the SFP module latch by pulling the
wire latch outward.
3.
With the SFP module latch in the unlocked position, remove the SFP module. For SFP modules that contain wire
tabs, grasp the wire latch and pull the SFP module out of the port.
4.
Replace the protective cap on the SFP module and the host port.
5.
Place the SFP module into a static-protective package.

Guidelines For Using Fibre Optic Cables

Do not route the cable along a folding cable management arm.
For devices on slide rails, leave enough slack in the cables so they do not bend to a diameter of less than 76 mm
(3 inch), or a radius less than 38 mm (1.5 inch), when extended or become pinched when retracted.
Route the cable away from places where it can be damaged by other devices in the rack cabinet.
Do not use plastic cable ties in place of the provided cable straps.
Do not over-tighten the cable straps or bend the cables to a diameter of less than 76 mm (3 inch) or a radius less
than 38 mm (1.5 inch).
Do not place excess weight on the cable at the connection point. Ensure that the cable is well supported.
22
Cables.