Cabinet Placement
The cabinet must meet the following criteria:
•
Minimum cabinet size and airflow are according to the EIA standard.
•
Minimum of 5 inches (12.7 cm) between the side intake and exhaust vents and the cabinet wall.
Rack Mounting
When you prepare your equipment rack, ensure that the rack is earth ground. The equipment rack must be
grounded to the same ground point used by the power service in your area. The ground path must be
permanent.
Fans and Airflow
Ventilation is side-to-side, with six fans on the left side of the switch that operate at a constant speed. For
proper ventilation, position the S25P chassis in an equipment rack (or cabinet) with a minimum of five
inches (12.7 cm) of clearance around the side intake and exhaust vents. When two S25P systems are
installed side by side, position the two S25P chassis at least 5 inches (12.7 cm) apart to permit proper
airflow. The acceptable ambient temperature ranges are listed in
As listed in
Table 4, "Status Panel LED Display," on page
status LED, which is green when the switch is operating within required temperature parameters and all
components are operating normally, including fans. The LED is amber when the temperature or
components are outside expected parameters, red in a major alarm.
SFTOS logs a temperature warning message when a temperature of 77 degrees C is reached, and logs
another message when the temperature returns to normal. The Command Line Interface (CLI) also reports
an alarm.
Use the
show logging
SFTOS Command Reference and SFTOS Configuration Guide.
In a stack, each unit has its own temperature monitoring and control. Status logging is identified by unit in
the system log.
Fan replacement in the field is not offered as an option.