Dell PowerConnect 7024F Aggiornamento del firmware - Pagina 20

Sfoglia online o scarica il pdf Aggiornamento del firmware per Interruttore Dell PowerConnect 7024F. Dell PowerConnect 7024F 24. Upgrading from version 2.x.x.x or 3.x.x.x or 4.x.x.x or 5.x.x.x to 5.1.9.3 firmware
Anche per Dell PowerConnect 7024F: Note di rilascio (27 pagine)

Dell PowerConnect 7024F Aggiornamento del firmware
Upgrading PowerConnect Switches from Version 2.x.x.x or 3.x.x.x or
4.x.x.x or 5.x.x.x to 5.1.9.3 Firmware
- # of sectors per cluster: 4
- # of reserved sectors:
- FAT entry size:
- # of sectors per FAT copy:
- # of FAT table copies:
- # of hidden sectors:
- first cluster is in sector #
- Update last access date for open-read-close = FALSE
Timebase: 66.666666 MHz, MEM: 266.666664 MHz, PCI: 66.666666 MHz, CPU: 533.333328 MHz
PCI unit 0: Dev 0xb314, Rev 0x01, Chip BCM56314_A0, Driver BCM56314_A0
SOC unit 0 attached to PCI device BCM56314_A0
Adding BCM transport pointers
Configuring CPUTRANS TX
Configuring CPUTRANS RX
hpc - No stack ports. Starting in stand-alone mode.
Instantiating /download as rawFs,
Formatting /download for DOSFS
Instantiating /download as rawFs, device = 0x20001
Formatting.../download: file system is marked clean, skipping check
OK.
<186> Apr 6 03:32:10 0.0.0.0-1 General[268434704]: bootos.c(225) 1 %% Event(0xaaaaaaaa)
(Unit 1 - Waiting to select management unit)>
Applying Global configuration, please wait ...
Applying Interface configuration, please wait ...
console>
5. After the switch has finished rebooting, log in and verify that the firmware has been updated to the
version using the show version command. A single switch will typically reboot in around two minutes. A
stack may take significantly longer to complete the upgrade process.
console#show version
System Description................ Dell Ethernet Switch
System Up Time.................... 0 days, 00h:05m:23s
System Contact....................
System Name.......................
System Location...................
Burned In MAC Address............. 5C26.0ACE.D9C7
System Object ID.................. 1.3.6.1.4.1.674.10895.3015
System Model ID................... PCM6220
Machine Type...................... PowerConnect M6220
unit image1
---- ----------- ----------- -------------- --------------
1
5.1.9.3
6. The switch or stack is now ready for normal operation. Verify the configuration and make any changes
needed prior to connecting the switch to the operational network.
1
FAT16
60
2
4
136
device = 0x20001
image2
current-active next-active
2.2.0.3
image1
Page 17
image1
5.1.9.3