On J-EX8200 switches, when a firewall filter is applied on the loopback (
the switch stops generating local ARP requests for transit traffic. As a workaround,
you can do the following:
Create firewall filters to block known unwanted traffic to the Routing Engine, and
then accept all other traffic.
Create firewall filters for specific hosts and all local subnets, and then discard all
other traffic.
[PR/486443]

J-Web Interface

In the J-Web interface, you cannot commit some configuration changes in the Ports
Configuration page and the VLAN Configuration page because of the following
limitations for port mirroring ports and port mirroring VLANs:
A port configured as the output port for an analyzer cannot be a member of any
VLAN other than the default VLAN.
A VLAN configured to receive analyzer output can be associated with only one port.
[PR/400814]
In the J-Web interface, uploading a software package to the switch might not work
properly if you are using Internet Explorer version 7. [PR/424859]
If an SRE module, RE module, SF module, line card, or Virtual Chassis member is in
offline mode, the J-Web interface might not update the dashboard image accordingly.
[PR/431441]
In the J-Web interface, in the Port Security Configuration page, you are required to
configure
when you configure
action
is not mandatory in the CLI. [PR/434836]
In the J-Web interface, interfaces configured with
in the Link Aggregation Configuration page. [PR/437410]
In the J-Web interface, in the OSPF Global Settings table in the OSPF Configuration
page, the Global Information table in the BGP Configuration page, or the Add Interface
window in the LACP Configuration page, if you try to change the position of columns
using the drag-and-drop method, only the column header moves to the new position
instead of the entire column. [PR/465030]
In the J-Web interface, in the OSPF Configuration page (Configuration > Routing >
OSPF), the Traceoptions tab in the Edit Global Settings window does not display the
available flags (tracing parameters). As a workaround, use the CLI to view the available
flags. [PR/475313]
When you have a large number of static routes configured and if you have navigated
to pages other than page 1 in the Route Information table in the J-Web interface
(Monitor > Routing > Route Information), changing the
routes refreshes the page but does not return to page 1. For example, if you run the
query from page 3 and the new query returns very few results, the Results table
Outstanding Issues in JUNOS Release 10.2 for J-EX Series Switches
even though configuring an
MAC limit
no-flow-control
lo0
) interface,
value
action
might be displayed
to query other
Route Table