Anche per Dell PowerEdge M610x: Manuale di aggiornamento (44 pagine), Manuale di aggiornamento (21 pagine), Manuale di aggiornamento (14 pagine), Manuale di installazione (7 pagine), Manuale introduttivo (12 pagine), Manuale introduttivo (12 pagine), Manuale del portafoglio (27 pagine), Manuale introduttivo (14 pagine), Manuale introduttivo (12 pagine)

Dell PowerEdge M610x Manuale tecnico
Dell
Thermal specifications for the PowerEdge M610x are detailed in Table 3 along with other important
operating and storage information.
Temperature
Operating
Storage
Relative Humidity
Operating
Storage
Maximum Vibration
Operating
Storage
Maximum Shock
Operating
Storage
Altitude
Operating
Storage

5.4 Acoustics

 Adherence to Dell's high sound quality standards. Sound quality is different from
sound power level and sound pressure level in that it describes how humans respond
to annoyances in sound, like whistles, hums, etc. One of the sound quality metrics in
the Dell specification is prominence ratio of a tone.
 Acoustical Performance of Typical Configuration. When installed in the M1000e
blade chassis, typical configuration
2
Typical configuration means projected average quantity, type, capacity, speed, etc., of components. Configuration for which
data reported is listed in the following table.
Dell PowerEdge M610x Technical Guide
Operating and Storage Specifications
Table 3.
o
o
10
to 35
C (50
o
10
C per hour
Note: For altitudes above 2950 feet, the maximum operating
temperature is derated 1
o
o
-40
to 65
C (-40
o
of 20
C per hour
20% to 80% (noncondensing) with a maximum humidity gradation of
10% per hour
5% to 95% (noncondensing) with a maximum humidity gradation of
10% per hour
0.26 Grms at 5-350 Hz in operational orientations
1.54 Grms at 10-250 Hz in all orientations
Half sine shock in all operational orientations of 31 G +/- 5% with a
pulse duration of 2.6 ms +/- 10%
Half sine shock on all six sides of 71 G +/- 5% with a pulse duration
of 2 ms +/- 10%
-15.2m to 3048 m (-50 to 10,000 ft)
Note: For altitudes above 2950 ft, the maximum temperature is
o
derated 1
F/550 ft
-16 to 10,600 m (-50 to 35,000 ft)
o
o
to 95
F) with a maximum temperature gradation of
o
F/500ft
o
o
to 149
F) with a maximum temperature gradation
2
of M610x blade results in the following idle
12