Christie LA5S Manuale d'uso - Pagina 12

Sfoglia online o scarica il pdf Manuale d'uso per Altoparlanti Christie LA5S. Christie LA5S 15. Recommended crossover and filter settings
Anche per Christie LA5S: Foglio di istruzioni (5 pagine)

Christie LA5S Manuale d'uso

Specifications

Audio

Specification
System type
Driver components
Crossover
a
Frequency response
Maximum sound pressure level
b
(SPL)
c
System coverage
a
Sensitivity
1 W/1 m
Recommended amplifier power
Rated impedance
a
Measured at distances of 4 m and 8 m, in free field and on ground plane. Sensitivity is calculated based on the
measured SPL response averaged in the 200 Hz-3 kHz range and scaled back to 1 m.
b
AES refers to AES2-2012 standard. IEC refers to IEC 60268-5 standard. Maximum continuous SPL is calculated
based on sensitivity and AES power handling. IEC short-term power is tested using IEC pink noise with a 9 dB crest
factor. The crest factor was specifically increased to reflect real life parameters of digital cinema soundtracks.
Maximum peak SPL is calculated using peak voltage during the IEC short-term power test.
c
Averaged in the 500 Hz -16 kHz range at -6 dB.
Christie Vive Audio LA5S Speaker User Manual
020-101277-02 Rev. 1 (07-2017)
Description
Coaxial parabolic ribbon driver line array, two-way, passive, single vented
enclosure.
Six 6 in. ribbon drivers with Kapton diaphragms and neodymium magnets and
six 6.5 in. paper/Kevlar composite mid-bass drivers with neodymium magnets.
Linear phase, 2-way, passive, symmetric crossover at 1.5 kHz, 24 dB/octave
60 Hz - 20 kHz @ -6 dB
130.5 dB (AES) continuous, 142.5 dB, peak
120° horizontal dispersion, 60° vertical dispersion
100.5 dB
990 W - 1400 W (FTC) at 7 Ohms / Christie CDA3, Christie CDA5, or Christie
CDA7.5 (depending on application)
7 Ohms
12