Miele G 2 Series Manuale - Pagina 24
Sfoglia online o scarica il pdf Manuale per Lavastoviglie Miele G 2 Series. Miele G 2 Series 46.
Anche per Miele G 2 Series: Manuale (14 pagine)
Technical Information
3. Release the Start/Stop button.
4. Immediately press the Start/Stop button 5 times; on the 5th time, hold
until the "Start/Stop" LED flashes.
5. Release the Start/Stop button.
6. If the "Start/Stop" LED does not light up, repeat the procedure.
Acknowledgement indicator:
The "Start/Stop" LED flashes rapidly (5 flashes per second).
Options:
For reset, water hardness and rinse aid settings, turn the selector switch to
the position indicated in Table 15. For all other settings, turn the selector
switch to the 11 o'clock position. The setting will be indicated via the flashing
rhythm of the "Rinse" LED. See Table 15.
Function
Reset
Water hardness setting
Dispensed rinse aid
quantity setting
Resetting standard
settings
Adjust wash temperature
Programming
Turn the selector switch to
the 1 o'clock position. To
reset all parameters to the
delivery condition, press
the Start/Stop button.
Turn the selector switch to
3 o'clock. To change the
water hardness setting,
press the Start/Stop
button.
Turn the selector switch to
the 5 o'clock position. To
change the dispensed
rinse aid amount, press
the Start/Stop button.
Press the Start/Stop
button 1x.Turn the selector
switch to 9 o'clock. To
reset all parameters to the
factory setting, press the
Start/Stop button.
Press the Start/Stop
button 3x.Turn the selector
switch to 3 o'clock. To
change the temperature,
press the Start/Stop
button.
24
G 1xxx/G 2xxx
Display
With this program function, all
parameters can be reset to the
delivery condition. The "Rinse" LED
flashes 1x briefly intermittently. If
the "Rinse" LED is off, at least one
setting was modified. If the "Rinse"
LED flashes, the parameters are as
in the delivery condition.
Setting range: 1 - 70 °d (1 - 74.9
gpg). If the "Rinse" LED flashes 4x,
this corresponds to the standard
setting of 12 - 15°d (12.8 - 16.1 gpg);
see Table 16.
The set value is indicated by the
"Rinse" LED flash pattern. If this LED
flashes 3x rapidly at intervals, this
corresponds to the standard setting
of 0.1 fl.oz. (3 mL). Range: 0 - 0.2
fl.oz. (0 - 6 mL); see Table 17.
With this programming function, all
parameters that can be modified by
the customer can be reset to their
factory settings. If the "Rinse" LED is
off, at least one setting was
modified. If the "Rinse" LED flashes,
the parameters are as in the factory
setting.
"Rinse" LED is off = wash
temperature per factory setting;
"Rinse" LED flashes = increased
wash temperature. Increased wash
temperature results in longer
running time.