G 1xxx/G 2xxx
Function
Softener sensor activation/
Water hardness setting
Dispensed rinse aid
quantity setting
Buzzer on/off
Adjust Sensor Wash
program (ID nos. -984 and
1
later)
Resetting standard
settings
Adjusting the main wash
temperature
(ID nos. -984 and later)
Final rinse temperature
modification (ID nos. -984
and later)
Programming
Press the options button
2x. The "Tab" LED flashes
2x quickly intermittently.
2
Press the Program button
as appropriate to make the
desired setting.
Press the options button
3x. The "Tab" LED flashes
3x quickly intermittently.
Press the Program button
as appropriate to make the
desired setting.
Press the options button
4x. The "Tab" LED flashes
4x rapidly intermittently.
Press Program to change
the setting.
Press the options button
5x. The "Tab" LED flashes
5x quickly intermittently.
Press the Program button
as appropriate to make the
desired setting.
Press the options button
12x. The "Tab" LED
flashes once slowly and 2x
quickly intermittently.
Press the Program button
to reset all standard
settings.
Press the options button
20x. The "Tab" LED
flashes 2x slowly
intermittently. Press the
Program button as
appropriate to make the
desired setting.
Press the options button
21x. The "Tab" LED
flashes 2x slowly and once
quickly intermittently.
Press the Program button
as appropriate to make the
desired setting.
21
Technical Information
Display
The display shows p and the digit/s
of the set value alternately. p0 =
Softener sensor active. Hardness
setting range: p1 to p70; see Table
14.
The display shows P and a digit
alternately: e.g., P3 (standard
setting) indicates a dispensed
quantity of 0.1 fl.oz. (3mL). Setting
range: 0 - 0.2 fl.oz. (0 - 6 mL).
The display shows P and a digit
alternately. Setting options: P0 =
Buzzer off; P1 = Buzzer on.
The display shows P and a digit
alternately. Setting options: P0 =
Standard program cycle (factory
setting); P1 = Adjusted program
cycle. The Sensor Wash program
can be adjusted in this parameter to
deal with stubborn soiling (if
otherwise low overall soiling). If this
option is selected, the main wash
temperature is increased to 131°F
and, as a result, the program
duration is extended.
This programmable function can be
used to reset all customer-modified
parameters back to their standard
settings. The display shows P and a
digit alternately. P0 = Settings have
been modified; P1 = All settings
reset to standard settings or no
modifications have been made.
The display shows p and a digit
alternately. Setting options: p0 =
Standard setting; p1 = Wash
temperature increased. If this option
is selected, the main wash
temperature is increased and, as a
result, the program duration is
extended.
The display shows p and a digit
alternately. Setting options: p0 =
Standard setting; p1 = Wash
temperature increased. If this option
is selected, the final rinse
temperature is increased and, as a
result, the program duration is
extended.