Allmand MAXI LITE II Manuale di avvio rapido - Pagina 3
Sfoglia online o scarica il pdf Manuale di avvio rapido per Apparecchiature industriali Allmand MAXI LITE II. Allmand MAXI LITE II 17.
SERIAL NUMBER 10-000001 & 11-000001
❏ Repeat the previous step when the temperature of the coolant is approximately
120 C (248 F). The resistance should not be less than 15 ohms,
Maxi Lite II Vert or LD series runs for 45-60 seconds before turning off:
❏ Check power from generator to main breaker and if 120 volts are not present,
then check the capacitor. If the capacitor passes the test then the issue is in the
generator end internally. * *See generator manufacturer manual for flashing tips.**
❏ If power is coming from the generator to the main breaker, look for a small 16
gauge black wire connected to the back side of the main breaker. Black wire gets
120 from the main breaker to the orange wire and into the relay. Make sure
power is measured correctly.
❏ Relay closes and green wire at the opposite end will send 12 volts to pin#4 of the
SLS to signify there is generator voltage. IF SLS does not receive power then the
unit will cut power to the fuel shut off solenoid hold wire.
❏ Check 2 amp inline fuse on orange wire. Replace if failed
❏ Check the relay and make sure it opens and closes. If failed replace it
❏ Check for loose crimps, faulty connections or loose grounds.If there is a break in
the line then tighten or replace.
❏
MAXI LITE II