7.4 Pre-blinking function.
This light flashes slowly (approximately once every two seconds) to warn the opening gate and quickly (approximately once a second) to warn clo-
sing gate.
1 2
3
4 5 6 7
8
9 10
1 2
3
4 5 6 7
8
9 10
7.5 Condominium function.
All inputs given remotely or by using the pulse button only open the gate. The door closes again automatically and as result, the automatic re-
closing function has to be actived, because the close command is ignored from the system (the close key is disabled).
1 2
3
4 5 6 7
8
9 10
1 2
3
4 5 6 7
8
9 10
7.6 Photocell test.
Every time the motor is switched on, the control unit automatically controls if the photocells are functioning properly. This operation increase the se-
curity system if a photocell is damaged (for instance output relay stuck) or in case of undesired photocell input short circuit.
This test is executed after the control unit has received an order of "moving", but before power is applied to the motor.
Installation notes:
Power supply to ALLMATIC photocells, or compatible types, must be connected to different terminals, depending on wheter it is necessary to activa-
te or de-activate testing on the photocells. The correct wiring diagram for a couple of photocells is the following:
13 14 15
24
TX
Wiring diagram with photocells
TEST ACTIVE (DIP6 OFF)
7.7 Methods for limit switch interventions.
The end of the opening and closing operations is entrusted to the set operational time and setting of dips 7
and 8.
NOTE: if limit switches are not installed, place dip 7-OFF and dip 8-ON:
7.7.1 Model ARGO2: If limit switches are installed, these operate in the following ways:
1 2
3
4 5 6 7
8
9 10
1 2
3
4 5 6 7
8
9 10
1 2
3
4
5 6
7
8 9 10
6-1622192
rev. 14
21/09/2012
ON
Pre-blinking function disabled
OFF
Pre-blinking function enabled. The gate motion is always signalized by a pre-blink, advising the user that
ON
OFF
the gate is ready to start. Pre-blinking time is fixed for 2 seconds approximately.
ON
Condominium function disabled.
OFF
ON
Condominium function enabled.
OFF
24
24
RX
TX
Wiring diagram with photocells
TEST NOT ACTIVE (DIP6 ON)
Type of limit switch
ON
Limit switch 1
OFF
Limit switch 2
Type of limit switch
ON
OFF
Limit switch 1
Limit switch 2
Type of limit switch
ON
OFF
Limit switches 1and
2 positioned for opening
Closing limit switch
13 14 15
24
RX
Function
End opening operation
End closing operation
Function
No operation
End closing operation
Function
Start of slowdown in
opening
No operation
ITA
ENG
FRA
ESP
DEU
DIP6 OFF: Photocells test enabled. The command is not
performed if the photocells are faulty.
DIP6 ON: Photocells test disabled.
Note: If the photocells test is active, the motor is delayed
by approximately one second from the moment in which
the order is received.
1 2
3
Arrest with limit switch: the end of the opening (limit
switch 1) or closing (limit switch 2) operations deter-
mined by the corresponding limit.
Arrest without opening limit switch: only the closing
selection is defined by time intervention of the corre-
sponding limit switch.
Start of slowdown only in opening: the start of slo-
wdown phase in opening is set off by the intervention
of both limit switches (one for each wing), while it is
only timed in closure (see diagram below)
POR
ON
OFF
4 5 6 7
8
9 10
5/9