Allmatic BIOS1 BRT Manuale per l'installazione - Pagina 8
Sfoglia online o scarica il pdf Manuale per l'installazione per Unità di controllo Allmatic BIOS1 BRT. Allmatic BIOS1 BRT 12. Programmable control board for barriers brt
7.3 Menu description:
7.3.1 Base settings menu
Auto reclosing time
Active when the barrier is in the completely open position or in partial opening, the barrier automatically closes after seconds. In this phase the
display shows
with the blinking dash, that during the last 10 seconds will be replaced by the count down.
Auto reclosing time after transit
If in the opening phase or in the completely open position the beam of the PH1 photocells is obscured and freed, the barrier automatically closes after
seconds when the completely open position is reached, In this phase the display shows
10 seconds will be replaced by the count down.
Motor torque
Adjust the motor torque to ensure a correct functioning of the barrier. It is possible to adjust the percentage of torque between 10% to 100%. After the
adjustement of this parameter it is recommended to perform a complete movimentation (opening and closing) to ensure a correct functioning of the
barrier.
Slowing down mode
The control unit has 2 different type of slowing downs : standard or with higher torque and speed.
Step by step configuration (SS)
= 0 Normal (OP-ST-CL-ST-OP-ST...)
Typical functioning of Step by Step. During the movement a SS command stops the barrier.
= 1 Alternated STOP (OP-ST-CL-OP-ST-CL...)
Alternated functioning with STOP during the opening. During the opening phase a SS command stops the barrier.
= 2 Alternated (OP-CL-OP-CL...)
The user cannot stop the barrier during the movement with a SS command.
A SS command during the movement inverts the movement.
= 3 Condominium – timer
A SS command only opens the barrier. When the barrier is completely open, if the command persist the control unit will wait until the opening
of the contact before beginning the contdown of the automatic reclosing (if enabled). Another SS command in this phase will restart the
contdown of the automatic reclosing.
= 4 Condominium with immediate auto reclosing
Like condominium – timer (previous point) but during the countdown a SS command will close the barrier, when it is in the completely open
position .
After black-out
When the control unit turns on after a black-out,
= 0 No action – when the control unit turns on the barrier does not move until the first command, the first movement is a slow opening.
= 1 Closing– turning on the control unit it will perform a slow closing.
Soft start
*
The movement begins with reduced torque, used in light gates.
*
Amplitude of slowing down
With this parameter it is possible to adjust the amplitude of the slowing down and eventually disable it (=0). If you need more precise or different
slowing down between opening and closing it is possible to set the parameter on (personalized) and perform an advanced learning of strokes
(6.2) providing also the beginning of slowing downs during the learning.
*
ATTENTION!
It is not advisable the disabling of the slowing downs and, if possible, use the "soft start" function.
6-1622245
rev.3
23/12/2016
ITA
ENG
FRA
ESP
DEU
POR
with the blinking dash, that during the last
8 / 12