Miele DA 227-2 Manuale operativo e di installazione - Pagina 25
Sfoglia online o scarica il pdf Manuale operativo e di installazione per Cappa di ventilazione Miele DA 227-2. Miele DA 227-2 40. Cooker
Lightly secure retaining plate A into
position using 5 x 40 mm screws
through the two holes and use the
notches to align with the middle line.
Drill 6 more holes Ø 8 mm through
the fitted retaining plate A.
Press 4 x S 8 plugs into the upper
two and lower two holes and then se-
cure the retaining plate in position
using four 5 x 40 mm screws.
Press two S8 R 60 plugs into both
middle holes.
Hold retaining plate B to the wall and
push up until it is directly below the
ceiling. Use the notches to align it
horizontally with the middle line.
Mark the 2 drill holes on the wall.
Drill two 8 mm ø holes into the wall,
and press the S8 plugs into the
holes.
Screw on the retaining plate with two
5 x 40 mm screws.
25