Preparation for extraction
^ When using C 150 mm ducting,
secure the exhaust connection
supplied to exhaust ducting with
hose clips.
^ Place the exhaust ducting on the fan
connection for the rangehood.
^ See "Connection for air extraction" for
further instructions on fitting the
ducting.
^ DA 2210: The rangehood has two
exhaust connections for use with two
150 mm diameter exhaust hoses.
A Y- adapter is supplied with the
rangehood. It may be used to feed
the exhaust from both connections to
a 200 mm diameter common duct.
dai2728
Installation