Silencer
(DASD 150 optional accessory)
To achieve even further reductions in
noise levels, a special silencer can be
fitted in the ducting system.
Connection for air extraction
...with air extraction:
The silencer not only reduces noise
from the fan, but also sounds from
outside (e.g. traffic noise).
For this reason, the silencer must be
positioned as close as possible to where
the ducting leaves the building a.
...in recirculation mode:
The silencer needs to be positioned
between the fan and the exhaust grille
b. The space needs to be checked in
some cases.
...air extraction with external fan:
To minimise noise from the fan in the
kitchen, the silencer should be
positioned in front of the external fan c
if possible, or if the ducting is long, then
in the ducting inside the rangehood
itself d.
In the case of an external fan placed
inside the house, fitting a silencer
behind the external fan e reduces the
noise of the fan outside the house.
In all modes of operation, the most
effective noise reductions are
achieved if two silencers are fitted in
the system.
35