Appliance dimensions
1) The front section of the wall housing
unit must be fitted with a shelf to the
depth of the partition wall.
If the appliance is installed further
back, e.g. if a lightshield is fitted, the
shelf must be deeper accordingly.
2) The partition wall in the wall unit must
be removable.
3) In extraction mode: when measuring
for the height of the wall housing unit
and the cut-out, account must be taken
of any accessories fitted, e.g. silencer.
4) Recirculation is possible with
conversion kit DUU 151.
18
Safety distances between cooktop
and rangehood (S)
The minimum safety distances
between the top of a cooktop and
the bottom of the rangehood are
as follows, unless a greater
distance is specified by the
manufacturer of your cooking
appliance:
Cooking appliance
Electric cooktop
Open electric grill
Deep fat fryer (electric)
Multi-burner gas cooktop
with maximum 45.4 MJ/h
total output, with no burner
having a greater output
than 16.2 MJ/h.
Multi-burner gas cooktop
with total output greater
than 45.4 MJ/h, or a gas
cooktop including a single
burner with an output
greater than 16.2 MJ/h.
Single gas cooktop with a
maximum output of
21.6 MJ/h
Single gas cooktop with a
maximum output greater
than 21.6 MJ/h
See "Warning and Safety"
instructions for further information.
Distance
S
600 mm
650 mm
650 mm
650 mm
760 mm
650 mm
760 mm