Miele DA 489-4 EXT Manuale operativo e di installazione - Pagina 20

Sfoglia online o scarica il pdf Manuale operativo e di installazione per Cappa di ventilazione Miele DA 489-4 EXT. Miele DA 489-4 EXT 40. Cooker
Anche per Miele DA 489-4 EXT: Istruzioni per l'uso e l'installazione (40 pagine)

Miele DA 489-4 EXT Manuale operativo e di installazione
Operation
Resetting the charcoal filter
operating hours counter
The indicator lamp for the charcoal filter
control will light up after the cooker
hood has operated for the number of
hours set. The charcoal filter must then
be replaced with a new one (see
"Cleaning and care").
Afterwards, the charcoal filter operating
hours counter must be reset.
^ Press and hold the charcoal filter
control for about 3 seconds while the
fan is switched on.
The indicator lamp for the control will
go out.
20
Reading the charcoal filter operating
hours counter
To check the percentage of time set
already used:
^ Press the On/Off control to switch the
fan on.
^ Press and hold the charcoal filter
control.
One or more of the indicator lamps for
the – / + controls will flash.
The number of flashing lamps shows
the percentage of the operating time
which has already been used up.
1 lamp
= 25 %
2 lamps = 50 %
3 lamps = 75 %
4 lamps = 100 %
The number of operating hours used
remains in the memory, even when the
appliance is switched off or there is a
power cut.