Miele DA 5391 W Istruzioni per l'uso e l'installazione - Pagina 17
Sfoglia online o scarica il pdf Istruzioni per l'uso e l'installazione per Cappa di ventilazione Miele DA 5391 W. Miele DA 5391 W 36. Miele ventilation system operating and installation instructions
Anche per Miele DA 5391 W: Dimensioni del prodotto (2 pagine), Manuale operativo e di installazione (40 pagine), Istruzioni per l'uso e l'installazione (36 pagine)
Grease filters
The reusable metal grease filters
remove solid particles from the vented
kitchen air (grease, dust, etc).
The grease filters should be cleaned
every 3 - 4 weeks or when the grease
filter indicator lights.
A dirty filter is a fire hazard.
^ To remove the grease filters pull the
locking clips, 1, forward. Lower the
filter 45°, 2, unhook it at the rear, 3,
and take it out. Support the grease
filter so that it does not fall onto the
cooktop.
Cleaning the grease filter
^ By hand: use a scrub brush with a
solution of warm water and mild
detergent.
Do not use the pure detergent,
aggressive all purpose cleaners,
oven sprays, abrasive cleaning
agents or limescale removers. They
could destroy the filter.
Cleaning and Care
^ In a dishwasher: place the filter
vertically in the lower basket, making
sure that the spray arm is not
blocked.
Use a hot temperature program,
e.g. "Heavy Soil" or "Pots and pans".
Use the recommended amount of
dishwasher detergent. Overuse could
destroy the filter.
Depending on the detergent,
cleaning the grease filters in a
dishwasher may cause permanent
discoloration of the filter surface.
Performance of the filter will not be
affected by this discoloration.
^ After cleaning, the filters can be
placed on a towel to air dry.
^ While the filters are removed, clean
any dirt or grease from the filter
casing to prevent the risk of fire.
When putting the grease filters back
make sure that the locking clips are
visibly facing the cooking surface.
If the filters are incorrectly installed,
insert a small screwdriver into the slit
along its edge to disengage it from the
casing.
^ After returning the grease filters,
press and hold the grease filter
button for 3 seconds to reset the
timer. The indicator light will go out.
^ If the grease filters are cleaned
before the grease filter timer has
reached its maximum, press the
grease filter button for 6 seconds to
reset the counter to zero.
17