Miele Novotronic T 220 Manuale di istruzioni per l'uso - Pagina 28

Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Asciugatrice Miele Novotronic T 220. Miele Novotronic T 220 44. Novotronic vented tumble dryer
Anche per Miele Novotronic T 220: Manuale di istruzioni per l'uso (44 pagine)

Miele Novotronic T 220 Manuale di istruzioni per l'uso

Electrical connection

Electrical connection U.K.

All electrical work should be carried out
by a suitably qualified and competent
person, in strict accordance with
national and local safety regulations.
Ensure power is not supplied to the
appliance until after installation work
has been carried out.
The appliance is supplied with a mains
cable with moulded plug ready for
connection to a 230-240V mains
supply. The voltage and connected
load are given on the data plate.
Please ensure these match the
household mains supply. The fuse
rating is quoted on the plug.
Connection should be made via a
suitable switched socket which is easily
accessible after installation.
For extra safety it is advisable to install
a residual current device (RCD), with a
trip current of 30 mA (in accordance
with DIN VDE 0664, VDE 0100 Section
739).
Do not connect via an extension lead.
Extension leads do not guarantee the
required safety of the appliance (e.g.
danger of overheating).
28
Non-rewireable plugs BS 1363
The fuse cover must be refitted when
changing the fuse, and if the fuse cover
is lost, the plug must not be used until a
suitable replacement is obtained. The
colour of the correct replacement cover
is that of the coloured insert in the base
of the plug, or the colour that is
embossed in words on the base of the
plug (as applicable to the design of
plug fitted).
Replacement fuses should be ASTA
approved to BS 1362 and have the
correct rating. Replacement fuses and
fuse covers may be purchased from
your local electrical supplier.
WARNING: THIS APPLIANCE
MUST BE EARTHED