Upward ducting via plastic vent
ducting* to wall vent*
Adapter* required.
1. Wall pipe*
2. Adapter*
3. Plastic ducting (external Ø 110 mm)
Connect the plastic vent ducting to the
dryer
1. Plastic ducting
2. Adapter* between exhaust
outlet and plastic ducting
Installation - Venting
Upward ducting via flexible vent
ducting* to exhaust flue
A = Wire wound spiral ducting
B = Flexible ducting
1. Wall pipe*
2. Adapter*
3. Flue / chimney, insulated against
damp
The exhaust air must not be vented
into a chimney or vent flue which is
in use. Neither should it be con-
nected to ducting which ventilates
rooms with fireplaces. It would be
dangerous if smoke or exhaust
fumes were drawn back into the
room!
31