Description of the machine
Program sequence and fault indicators
On
Drying
Cool air
Anti-crease/End
Check venting
Check lint filter
Fault messages
Faults or interruptions are indicated by the se-
quence lights/fault indicators flashing.
Heating
(flashes)
Safety period
(flashes
)
Gas/Venting
(lights up)
Lint filter
(lights up)
The messages are:
"Heating"
Fault in the heating system.
Action: Call Miele's Technical Service
Department.
"Safety period"
The maximum running time of the drying pro-
gram was exceeded because the residual
moisture at the start of the program was too
high.
Action: Restart the drying program.
If the fault message occurs again contact the
Miele Technical Service Department.
"Venting"
The venting duct is obstructed.
Action: Check the vent ducting and clean if
necessary.
"Lint filter"
The lint filter is clogged.
Action: Clean the lint filter at the end of the pro-
gram.
Note:
The "Drying", "Cool air" and "Anti-crease" indi-
cators will flash if there is a power failure or if
a program has been interrupted (e.g. when a
door has been opened). They do not indicate
a fault. The indicators will stop
flashing once the "Start" button is pressed.
10