INSTRUCTION MANUAL OPTIONS
OPTION DATA LOGGER
The UltraMaXX offers the option of saving predetermined
parameters at a fixed time interval via 4 parallel data reg-
isters. These saved values can be read out by authorised
service personnel using the service software via the M-Bus
option or via the optical interface. It is not possible to display
the values via the LCD display.
Annual logger
For 16 years, up to 6 parameters are stored once a year at
24:00 on a defined day.
Monthly logger
For 48 months, up to 6 parameters are stored at 24:00 on
the last day of the month.
Daily logger
For 460 days, up to 6 parameters are stored daily at 24:00.
Programmable logger
Up to 6 parameters are stored for 1500 steps, with a
programmable time ranging from 1 minute up to 7 days.
The time and the internal error messages are also saved
for all loggers. If the maximum number of stored values of
a logger is reached, the oldest value is discarded and the
new value is stored (rolling circulation) for each subsequent
scheduled storage.
18
Parameters that can be stored
• Volume water meter 1
• Volume water meter 2
• Volume water meter 3
• Volume water meter 4
• Volume
• Volume tariff 1
• Volume tariff 2
• Heat energy
• Cold energy
• Current maximum flow rate
• Time of current maximum flow rate
• Current maximum power
• Time of current maximum power
• Current maximum supply temperature
• Time of current maximum supply temperature
• Time tariff 1
• Time tariff 2
• Energy tariff 1
• Energy tariff 2
• Flow rate
• Return temperature
• Supply temperature
• Power
Each data logger can be assigned up to 6 parameters
individually. The parameters are programmed by authorised
service personnel using the service software via the M-Bus
option or via the optical interface.
NOTES