Bürkert Magnetventil 6013 Istruzioni per l'uso - Pagina 2
Sfoglia online o scarica il pdf Istruzioni per l'uso per Unità di controllo Bürkert Magnetventil 6013. Bürkert Magnetventil 6013 4. 2/2-way solenoid valve
Destruction of the coil by overheating!
▶ Connect the coil electrically only when the housing has been installed.
In the case of AC voltage pay attention to movable core.
To prevent injury, ensure that:
▶ Do not supply the medium connectors of the system with aggressive
or flammable mediums.
▶ Do not make any external modifications to the device bodies. Ensure
that the system cannot be activated unintentionally.
▶ Installation and repair work may be carried out by authorized techni-
cians only and with the appropriate tools.
▶ After an interruption in the power supply or pneumatic supply, ensure
that the process is restarted in a defined or controlled manner.
▶ Do not put any loads on the body.
▶ Observe the general regulations of technology.
4
Medium temperature:
Operating
Sealing material
principles
CFA
FKM
PTFE/Graphite
CFB
FKM
Ambient temperature:
-10 ... +55 °C
Viscosity:
21 mm/s
Protection class:
IP65 in accordance with EN 60529 with
cable plug
Media:
neutral gaseous and liquid media, which do not attack
body and sealing materials (see table of resistance under
www.burkert.com)
Check resistance in individual cases
4.5 Type label (example)
Sealing material
Orifice
Circuit function
Type
6013 A 2,0 FKM MS
G1/8 PN 0 - 10 bar
24V
00450000
Ident. no.
Voltage, Frequency, Output
Nominal connection pressure
6
english
Medium temperature
-10 ... +100 °C (PA Coil)
-10 ... +120 °C (Epoxide Coil)
-10 ... +180 °C
-10 ... +100 °C (AC)
-10 ... +120 °C (DC)
Body material
50Hz
7W
WXXXX
if applicable
english
4
TECHNICAL DATA
4.1 Conformity
In accordance with the EC Declaration of conformity, the solenoid
valve Type 6013 is compliant with the EC Directives (if applicable).
4.2 Standards
The applied standards, which verify conformity with the EC Directives,
can be found on the EC-Type Examination Certificate and / or the EC
Declaration of Conformity (if applicable).
4.3 Operating conditions
WARNING!
Heat sources and temperature fluctuations may cause malfunc-
tions or leaks!
▶ If the device is used outdoors, do not expose it unprotected to the
weather conditions.
▶ Avoid heat sources which may cause the allowable temperature
range to be exceeded.
4.4 Fluidic data
Operating principle
2 (A)
A
2/2-way valve, normally closed
(NC)
1 (P)
2 (B)
B
2/2-way valve, normally open
(NO)
1 (P)
Pressure range:
see type label
Line connectors:
Type 6013: G1/8, G1/4, G3/8, Flange
Type 6013A: G1/8, G1/4
Note the information specified on the type label for voltage, type
of current, and pressure.
english
4.6 Electrical data
Connections:
DIN EN 175301-803 Form A
for cable plug Type 2508
Supply voltage:
Type 6013: 24 V DC ± 10 %
max. residual ripple 10 %
24 V / 50 Hz
230 V / 50 Hz
Type 6013A: 24 V DC ± 10 %
max. residual ripple 10 %
230 V / 50 Hz
± 10 %
Voltage tolerance:
Nominal output:
CFA: 8 W (5 W, 10 W)
CFB
AC: 7 W (9 W)
DC: 8 W
Impulse version DC: 7 W
Nominal operating mode:
100 % continuous operation
for block installation:
5 W continuous operation
on request a. A.
8 W intermittent operation 60 %
(30 min)
Type 6013