INSTALLATION STEPS:

1. Secure the mounting bracket onto application surface by means of hole pattern on mounting bracket [Fig.1a]
Feed source wire through center oval opening of mounting bracket [Fig.1b]
[
LIGHT FIXTURE AIMING REQUIRED
2. Loosen center pivoting M10 hex bolt [do not remove] on both sides of light fixture [Fig.2]
3. Remove the angle locking M6 bolts on both sides [Fig.3]
4. Aim light fixture to desired angle [Fig.4]
5. Re-install angle locking M6 hex bolts on both sides [Fig.3] ................................................ suggested torque = 5 ft.lb. [6.8 Nm]
6. Tighten the center pivoting M10 hex bolts on both sides [Fig.2] ...................................... suggested torque = 25 ft.lb [33.9 Nm]
[
NO LIGHT FIXTURE AIMING REQUIRED
2. Secure angle locking M6 hex bolts on both sides [Fig.3] ..................................................... suggested torque = 5 ft.lb. [6.8 Nm]
3. Tighten the center pivoting M10 hex bolts on both sides [Fig.2] ....................................... suggested torque = 25 ft.lb [33.9 Nm]
1501 Route 34 South, Farmingdale, NJ 07727
Dialig
ht de México S.R.L de C.V. Calle Lirios s/n Col. Carlos Pacheco, Ensenada Baja California, México C.P. 22830
FLOODLIGHT - "FL" SERIES
INSTALLATION INSTRUCTIONS
100-277 VAC / 347-480 VAC
IMPORTANT: Make sure application surface can handle weight of light fixture
Fig.1a
]
]
Fig.2
Fig.3