Alloy Home MH4 Manuale - Pagina 10

Sfoglia online o scarica il pdf Manuale per Termostato Alloy Home MH4. Alloy Home MH4 12. Electrical heating thermostat

Alloy Home MH4 Manuale
No.
Parameter
P10
Floor Protection Temp
Backlash Value
P11
Remote Control Mode
Temp Setting
P12
Factory Reset
P13
Heating Temp
Increasing Speed
P14
Celsius/Fahrenheit

TROUBLESHOOTING

Problem
Thermostat functions but no
heat from the system
No Display
GFCI is tripped
Default
Range
5°C (9°F)
0.5~10°C
(01~18°F)
16.5°C
5~37°C
(62°F)
(41~99°F)
53
0~99
5
0-99
OC
OC/OF
Solution
1. Check wiring instructions and wire identification
2. If the GFCI is tripped, reset the thermostat with the side switch
3. Check the resistance of the floor warming system. Refer to the
cable manufacturer installation manual
Check wiring connection on the back of the unit
1. Check wiring connections
2. Reset thermostat by switching off then back on
3. Check resistance of the floor warming system. Refer to the
cable manufacturer installation manual
Note
Set to 55 then press S3
to confirm Factory Reset
OC: Celsius
OF: Fahrenheit
(After settings modification,
to restore factory settings)