3-1. Serial Number And Rating Label Location

The serial number and rating information for this product is located on the back panel. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on cover of this manual.

3-2. Specifications*

Coolant Tank
Capacity
Model
Hydracool 1
8 L
8 L
Hydracool 2
8 L
8 L
*IEC Cooling Capacity States That The Water Inlet Temperature Can Not Exceed 40°C Above Ambient Temperature At A 1l/ Min Flow Rate.
**Plug Is Customer Supplied.
Recirculating Coolant System For Water-Cooled GTAW Torches And GMAW Guns.
Use With Guns/Torches Rated Up To 600 Amperes.

3-3. Coolant Specifications

Do not use conductive coolant.
Application
GTAW Or Where High Frequency Current Is Used
GMAW Or Where High Frequency Current Is Not Used
Where Coolant Contacts Aluminum Parts
*Coolants 043810 and 043809 protect to -38
NOTICE − Use of any coolant other than those listed in the table voids the warranty on any parts that come in contact with the coolant (pump, radiator,
etc.).

3-4. Environmental Specifications

A. IP Rating
This equipment is designed for indoor use and is not intended to be used or stored outside.
SECTION 3 − SPECIFICATIONS
Maximum Cooling
Capacity
1670 Watts
(5698 BTU/hr)
1.0 L/min
(1.1 qt/min)
1670 Watts
(5698 BTU/hr)
1.0 L/min
(1.1 qt/min)
1760 Watts
(6005 BTU/hr)
1.0 L/min
(1.1 qt/min)
1760 Watts
(6005 BTU/hr)
1.0 L/min
(1.1 qt/min)
Coolant 050024004
Low Conductivity Coolant 043810*
Distilled Or Deionized Water Okay Above 0
Coolant 050024004
Low Conductivity Coolant 043810*
Aluminum Protecting Coolant 043809*
Distilled Or Deionized Water Okay Above 0
Aluminum Protecting Coolant 043809*
°
°
C (-37
F) and resist algae growth.
Hydracool 1 IP21
Hydracool 2 IP23
This equipment is designed for outdoor use.
Input Power
Cord with
Plug
Input Power
Single Phase
2 m
115 VAC
50/60 Hz
2.5 Amperes
Single Phase
2 m**
230 VAC
50/60 Hz
1.3 Amperes
Single Phase
2 m
115 VAC
50/60 Hz
2.5 Amperes
Single Phase
2 m**
230 VAC
50/60 Hz
1.3 Amperes
IP Rating
IP Rating
Dimensions
Length: 305 mm
Height: 674 mm
Width: 263 mm
Length: 305 mm
Height: 674 mm
Width: 263 mm
Length: 585 mm
Height: 286 mm
Width: 324 mm
Length: 585 mm
Height: 286 mm
Width: 324 mm
Coolant
°
°
C (32
F)
°
°
C (32
F)
OM-254203 Page 5
Weight
20.7 kg
20.7 kg
20.8 kg
20.8 kg
IP21 2014−06
IP23 2017−02