4-1. Serial Number And Rating Label Location

The serial number and rating information for this product is located on the front panel. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on cover of this manual.

4-2. Specifications

.
The correction factor on the cooling power at an ambient temperature of 1045F (405C) is 0.625.
Recirculating Coolant System For Water-Cooled GTAW Torches And GMAW Guns.
Use With Guns/Torches Rated Up To 600 Amperes.
Coolant Tank Capacity
Rated Cooling Power
Maximum Cooling Power
Dimensions (Length x Width x Height)
Weight
Input Voltage
Input Amperage

4-3. Coolant Specifications

Do not use conductive coolant.
Application
GTAW Or Where High Frequency Current Is Used
GMAW Or Where High Frequency Current Is Not Used
Where Coolant Contacts Aluminum Parts
*Coolants 043810 and 043809 protect to -37
NOTICE − Use of any coolant other than those listed in the table voids the warranty on any parts that come in contact with the coolant (pump, radiator,
etc.).

4-4. Environmental Specifications

A. IP Rating
This equipment is designed for outdoor use. It may be stored, but is not intended to be used for welding outside during precipitation unless
sheltered.
B. Information On Electromagnetic Compatibility (EMC)
!
This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low−
voltage supply system. There can be potential difficulties in ensuring electromagnetic compatibility in those locations, due to con-
ducted as well as radiated disturbances.
This equipment complies with IEC 61000-3-11 and IEC 61000-3-12.
C. Temperature Specifications
Operating Temperature Range
14 to 104 °F (-10 to 40°C)
.
A complete Parts List is available at www.MillerWelds.com
SECTION 4 − SPECIFICATIONS
3.5 gal (13.2 L)
1.66 kW at 1.1 qt/min at 77°F (5600 BTU/hr at 1 L/min at 25°C)
4.14 kW at 5.0 qt/min at 77°F (14,000 BTU/hr at 4.7 L/min at 25°C)
26 x 15.75 x 11.75 in. (660 x 400 x 298 mm)
60 lb (27 kg)
115 VAC, Single Phase, 50 or 60 Hz
5.9A 50Hz
4.7A 60Hz
Low Conductivity Coolant 043810*
Distilled Or Deionized Water Okay Above 32
Low Conductivity Coolant 043810*
Aluminum Protecting Coolant 043809*
Distilled Or Deionized Water Okay Above 32
Aluminum Protecting Coolant 043809*
°
°
F (-38
C) and resist algae growth.
Coolant
IP Rating
IP23S
Storage/Transportation Temperature Range
-4 to 131 °F (-20 to 55°C)
°
°
F (0
C)
°
°
F (0
C)
IP23 2014−06
ce-emc 4 2014-07
Temp1_2016- 08