SECTION 5 − ELECTRICAL DIAGRAMS
Product
Input Votage
(3-Phase)
220 VAC
230 VAC
400 VAC
CST 250
CST 250
440 VAC
460 VAC
575 VAC
220 VAC
230 VAC
400 VAC
CST 280
CST 280
440 VAC
460 VAC
575 VAC
230 VAC
Maxstar 200
Maxstar 200
460 VAC
* Full output from power source may cause rack line fuses to blow. Reduce output to 235 amperes.
** Full output from power source may cause rack line fuses to blow. Reduce output to 245 amperes.
{ Rack is supplied with 25 ampere fuses. No fuse kit is available.
Figure 4-1. Circuit Diagram For Control Panel In Racks
Table 4-1. Fuse Size Requirements
Amperage Input
Recommended
At Rated Load
Line Fise Size
Output, 50/60
(Amps)
Hz
32.1
30.5
30**
18.2
16.4
14.7
11.6
34.2
33.5
30**
19.7
18.1
17.4
14.3
18.4
8.9
Miller Fuse Kit
Part No.
(12 pcs)
30*
195 349
195 349
25
{
25
{
25
{
20
195 348
30*
195 349
195 349
25
{
25
{
25
{
20
195 348
30
195 349
15
195 347
208 333
Individual Fuse
Bussman Fuse
Part No.
Part No.
199 795
KTK-R-30
199 795
KTK-R-30
220 513
KTK-R-25
220 513
KTK-R-25
220 513
KTK-R-25
212 541
KTK-R-20
199 795
KTK-R-30
199 795
KTK-R-30
220 513
KTK-R-25
220 513
KTK-R-25
220 513
KTK-R-25
212 541
KTK-R-20
199 795
KTK-R-30
220 514
KTK-R-15
OM-213 592 Page 21