4-7. Connecting 115 Volts Input Power For Diversion 180 Models

!
Installation must meet all National and Local Codes
− have only qualified persons make this installation.
!
Special installation may be required where gasoline or
volatile liquids are present − see NEC Article 511 or CEC
Section 20.
.
The Auto-Line circuitry in this unit automatically links the
power source to the primary voltage being applied, either
115 or 230 VAC.
For 115 volts AC input power, a 15 or 20 ampere individual
branch circuit protected by time-delay fuses or circuit breaker is
required.
1
Multi-Voltage Plug And Power Cord Connector (NEMA
Type 5−15P Plug Shown)
For multi−voltage plug connections, see Section 4-9.
2
Receptacle − NEMA Type 5−15R (Customer Supplied)
1
2
Ref. 805 474-A