Diametral AC250K2D-S Manuale - Pagina 4

Sfoglia online o scarica il pdf Manuale per Alimentazione Diametral AC250K2D-S. Diametral AC250K2D-S 12. Ac power supply

1
- display for setup of the voltage value
- output indicator – the light signalize the presence of a voltage on the output
2
3
- indicator for confirmed/unconfirmed set voltage value by pressing ENTER
4
- controlling keyboard
5
- main switch for the mains
- output safety fuse – protect the output against a short circuit
6
7
- output socket
8
- voltmeter for the real voltage value - shows the real output voltage
- numeric keys – serve for setup of the requested voltage value
9
10 - key UP – by pressing this key the output voltage increases by 1V
11 - key DOWN – by pressing this key the output voltage decreases by 1V
12 - key LOCAL – pressing of this key allows to interrupt the communication with the parent
computer
13 - switch knob for the source output - connect and disconnect the voltage from the output
14 - key ENTER – pressing of this key serves to confirm the set voltage value
15 - key CLEAR – pressing of this key serves to change the faulty set voltage value and by
long pressing of this key you can go to MENU (only for model AC250KxD-S)
Indicator OUT (2) is not lighting
Indicator OUT (2) is lighting
Indicator SET (3) is blinking
Indicator SET (3) is lighting
IV. Safety instructions
1)
The device is equipped by fixed flex cable and can be connected only to the
alternating voltage 230 V/50H with a safety plug!
2)
Keep this device out of children!
3)
Do not use the device on humans and animals!
4)
The device can be operated at schools and at other working places only under a
control of persons trained to this effect!
5)
Do not operate the device and the connected electrical appliances without oversight!
6)
All reparations, incl. change of the damaged power flex cable have to be done only in
service designated by the manufacturer!
7)
Never use different safety fuse than is described in the instruction manual!
8)
When operating the device do not wear any jewellery, circlets and other conductive
articles!
9)
When the device is in operational mode, a dangerous voltage could appear on the
outgoing connectors.
10) Never switch-on the device immediately after bringing it from a cold environment to a
warm one. Keep it switched-off to get the same temperature as the surroundings!
11) Do not cover with anything the air vents and ventilator! In the case of infringement this
rule it could cause a damage of the device!
12) During a malfunction of the device could appear on the outgoing connectors the
voltage 290V!
- 4 -
-
no
voltage
on
outgoing relay does not make the
contact
- a setup voltage value is on the
output, outgoing relay makes the
contact
- the setup voltage is not confirmed
by pressing ENTER, on the output
is the original voltage value
- the setup voltage is confirmed
and carried to the output (if the
output is connected)
the