Miller XMT 450 CV Manuale d'uso - Pagina 37

Sfoglia online o scarica il pdf Manuale d'uso per Sistema di saldatura Miller XMT 450 CV. Miller XMT 450 CV 48. With arcreach

Miller XMT 450 CV Manuale d'uso
SECTION 9 – SMAW/CAC-A OPERATION
9-1.

Typical Connection For SMAW And CAC-A Process

2
1
Turn
off
power
before
connections.
1 Electrode Holder (Carbon Arc)
For CAC-A process connect carbon arc cut-
ting torch to to positive weld output terminal.
2 Electrode Holder
4
3
7
3 Positive (+) Weld Output Terminal
making
4 Remote 14 Receptacle
Connect desired remote control to remote
14 receptacle as required.
5 Compressed Air LIne
5
6
6 Negative (-) Weld Output Terminal
7 Workpiece
Ref. 277781-C
OM-292663 Page 33