Burkert 2300 Series Manuale di istruzioni per l'uso - Pagina 4

Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Posizionatori di valvole Burkert 2300 Series. Burkert 2300 Series 12. Remote-positioner, installation on process valves with internal air flow
Anche per Burkert 2300 Series: Manuale di avvio rapido (19 pagine), Istruzioni aggiuntive (12 pagine)

Burkert 2300 Series Manuale di istruzioni per l'uso
Tightening torques of spindle guide
Spindle
Orifice body
(mm)
diameter
(mm)
10
15
20 / 25
32
14
25
32 - 50
22
65
Tab. 2:
Tightening torques of spindle
*) If the valve features a PEEK spindle guide, we recommend replacing it with a
VA spindle guide. They are available from your Bürkert sales office.
8
Type 2702:
For control function A (CFA) pressurize the lower control air
connection with compressed air (6 bar): Valve opens.
(For control function B the valve is already open).
Both types:
Screw actuator into the valve body. Observe tightening torque
(see "Tab. 3").
Turn off the pressure and vent the lines.
Tightening torque of valve body / nipples
Orifice (mm)
15
20
25
32
40
50
65
Tab. 3:
Tightening torque of valve body / nipples
Material of spindle
Tightening
guide
torque (Nm)
PEEK*
6
1.4401 / 1.4404 / 316L
15
25
50
PEEK*
15
1.4401 / 1.4404 / 316L
25
60
1.4401 / 1.4404 / 316L
60
Tightening torque [Nm]
45 ± 3
50 ± 3
60 ± 3
65 ± 3
70 ± 3
70 ±3

INSTALLING THE ACTUATOR

WARNING!
Danger if incorrect lubricants used!
Unsuitable lubricant may contaminate the medium. In oxygen appli-
cations there is a risk of an explosion!
▶ In specific applications, e.g. oxygen or analysis applications, use
appropriately authorised lubricants only.
Check the graphite seal and if required, replace it.
Grease nipple thread before re-installing the actuator (e.g. with
Klüber paste UH1 96-402 from Klüber).
NOTE!
Damage to the seat seal or the seat contour!
▶ When installing the actuator, ensure that the valve is in open
position.
Type 2300:
Control function A (CFA) and I (CFI)
Without unit control: pressurize the pilot air port
1 with compressed air (5 bar): valve opens.
(For CFB the valve is already open).
With unit control: open the valve according to
the operating instructions for the control unit.

INSTALLATION TOOLS

Installation wrench for packing gland (only for PEEK spindle guide)
Installation wrench
Spindle ∅ 10 mm
Spindle ∅ 14 mm
Tab. 4:
Installation wrench
Modified socket wrench for packing gland and VA spindle
guide (Series production status since April 2012)
Socket wrench
Spindle ∅ 10 mm
Spindle ∅ 10 mm
Spindle ∅ 14 mm
Tab. 5:
Modified socket wrench
Special wrench for rotating the actuator
(only for actuator without hexagon)
Order no.
665 702
Tab. 6:
Special wrench
If you have any queries, please contact your Bürkert sales
office.
Type 2300
Pilot air port
2
1
Order no.
665 700
665 701
Orifice
AF
Order no.
15
19
683 220
20 - 32
21
683 222
25 - 50
21
683 223
9